Home> Products>Split Condensing Steam Boiler

Split Condensing Steam Boiler

Split Condensing Steam Boiler

  • Capacity: 1-20 t/h
  • Design fuel: Natural gas, coal gas
  • Application: Steam supply for industry production and central heating
  • Description: Classic structure with three passes; self-designed and self-developed PLC auto control system, more intelligent, more precise, and more fitted to our boilers
  • Chat Online Message Send E-mail

Introduction

The burner is fixed on the front wall of the boiler. After ejected by the burner, the fuel fires in micro positive pressure in the furnace (the first pass). High temperature smoke from the burning firstly turns 180° to the left at the end of the furnace, secondly enters convection tubes in the second pass towards the front of the furnace, thirdly turns 180° to the left and enters the economizer and condenser (the third pass) to fully transfer heat with fin tubes, and lastly enters the atmosphere.

Features

  1. High Steam Quality and High Thermal Efficiency
  2. Sufficient and Steady Capacity
  3. Environmental Protection and Energy Conservation
  4. Sufficient Heat Transfer
  5. Easy Operation and Maintenance
  6. Long Service Time
  7. Safety and Reliability

Technical parameters

Model Unit WNS1
1.0-YQ
WNS2
1.0-YQ
WNS2
1.25-YQ
WNS3
1.25-YQ
WNS4
1.25-YQ
WNS6
1.25-YQ
WNS8
1.25-YQ
WNS10
1.25-YQ
WNS10
1.6-YQ
WNS15
1.25-YQ
WNS15
1.6-YQ
WNS20
1.25-YQ
Rated evaporation t/h 1 2 2 3 4 6 8 10 10 15 15 20
Corresponding calorific value 104kcal/h 64 128 128 192 256 384 512 640 640 960 960 1280
Combustion control mode Fully automatic two-piece fire Full automatic ratio adjustment
Fuel consumption Diesel kg/h 64.4 128.9 128.9 193.3 257.7 386.6 514.4 644.3 644.3 966.5 966.5 1288.6
Heavy oil kg/h 67 134 134 200.9 267.9 401.9 535.8 669.8 669.8 1004.7 1004.7 1339.6
Natral gas Nm³/h 70.8 141.5 141.5 212.3 283 424.6 566.1 707.6 707.6 1061.4 1061.4 1415.2
City gas Nm³/h 143.7 287.4 287.4 431.2 574.9 862.3 1149.8 1437.2 1437.2 2155.9 2155.9 2874.5
Electric power Oil KW 3.55 8.9 8.9 14 16 18 29 34 34 69 69 2874.5
Gas KW 3.2 8.5 8.5 13 16 18 29 34 34 61 61 67
Boiler max size A mm 3830 4860 5020 5110 6110 6950 7530 8300 8300 8750 8750 9620
B mm 1900 2670 2560 2790 2800 2910 3390 3260 3310 3500 3500 5180
C mm 3010 3290 3250 3490 3640 3830 4350 4320 4320 4430 4430 5270
Valve pressure MPa 1.6(2.5)
Steam outlet-DN mm 50 65 65 80 100 125 125 150 150 200 200 200
Water inlet-DN mm 40 40 40 40 40 40 40 50 50 50 50 65
Drain diameter-DN mm 40 40 40 50 50 50 50 50 50 50 50 50
Chimney diameter mm 300 350 350 450 450 550 550 700 700 900 900 900
Weight t 5.6 8.2 12.1 16 11.3 16.7 21.9 25.9 28.2 34.9 39.3 41.9
General Rated steam temperature (184)194(204) Rated thermal efficiency % 97-100 Combustion mode MPa Microbarotropic combustion
Rated water inlet temperature 20 Rated steam pressure MPa (1)1.25(1.6) Power supply V/Hz 380/50

Fuel consumption is the number after the condenser is installed; Fuel calorific value: heavy oil 9860kcal/kg, diesel 10250kcal/kg, natural gas 9140kcal/Nm cubed, liquefied petroleum gas 24998kcal/Nm cubed, city gas 4500kcal/Nm³;

As the technology is constantly updated, it is subject to change without notice. For detailed parameters, please refer to the headquarters of Fangkuai boiler co., LTD.

Messages